mne.set_bipolar_reference¶
-
mne.
set_bipolar_reference
(inst, anode, cathode, ch_name=None, ch_info=None, drop_refs=True, copy=True, verbose=None)[source]¶ Re-reference selected channels using a bipolar referencing scheme.
A bipolar reference takes the difference between two channels (the anode minus the cathode) and adds it as a new virtual channel. The original channels will be dropped.
Multiple anodes and cathodes can be specified, in which case multiple virtual channels will be created. The 1st anode will be subtracted from the 1st cathode, the 2nd anode from the 2nd cathode, etc.
By default, the virtual channels will be annotated with channel info of the anodes, their locations set to (0, 0, 0) and coil types set to EEG_BIPOLAR.
- Parameters
- instinstance of
Raw
|Epochs
|Evoked
Data containing the unreferenced channels.
- anode
str
|list
ofstr
The name(s) of the channel(s) to use as anode in the bipolar reference.
- cathode
str
|list
ofstr
The name(s) of the channel(s) to use as cathode in the bipolar reference.
- ch_name
str
|list
ofstr
|None
The channel name(s) for the virtual channel(s) containing the resulting signal. By default, bipolar channels are named after the anode and cathode, but it is recommended to supply a more meaningful name.
- ch_info
dict
|list
ofdict
|None
This parameter can be used to supply a dictionary (or a dictionary for each bipolar channel) containing channel information to merge in, overwriting the default values. Defaults to None.
- drop_refsbool
Whether to drop the anode/cathode channels from the instance.
- copybool
Whether to operate on a copy of the data (True) or modify it in-place (False). Defaults to True.
- verbosebool,
str
,int
, orNone
If not None, override default verbose level (see
mne.verbose()
and Logging documentation for more). If used, it should be passed as a keyword-argument only.
- instinstance of
- Returns
See also
set_eeg_reference
Convenience function for creating an EEG reference.
Notes
If the anodes contain any EEG channels, this function removes any pre-existing average reference projections.
During source localization, the EEG signal should have an average reference.
The data must be preloaded.
New in version 0.9.0.