mne.io.read_raw_kit¶
-
mne.io.
read_raw_kit
(input_fname, mrk=None, elp=None, hsp=None, stim='>', slope='-', stimthresh=1, preload=False, stim_code='binary', allow_unknown_format=False, standardize_names=False, verbose=None)[source]¶ Reader function for Ricoh/KIT conversion to FIF.
- Parameters
- input_fname
str
Path to the sqd file.
- mrk
None
|str
| array_like, shape (5, 3) |list
ofstr
or array_like Marker points representing the location of the marker coils with respect to the MEG Sensors, or path to a marker file. If list, all of the markers will be averaged together.
- elp
None
|str
| array_like, shape (8, 3) Digitizer points representing the location of the fiducials and the marker coils with respect to the digitized head shape, or path to a file containing these points.
- hsp
None
|str
|array
, shape (n_points, 3) Digitizer head shape points, or path to head shape file. If more than 10,000 points are in the head shape, they are automatically decimated.
- stim
list
ofint
| ‘<’ | ‘>’ Channel-value correspondence when converting KIT trigger channels to a Neuromag-style stim channel. For ‘<’, the largest values are assigned to the first channel (default). For ‘>’, the largest values are assigned to the last channel. Can also be specified as a list of trigger channel indexes.
- slope‘+’ | ‘-’
How to interpret values on KIT trigger channels when synthesizing a Neuromag-style stim channel. With ‘+’, a positive slope (low-to-high) is interpreted as an event. With ‘-’, a negative slope (high-to-low) is interpreted as an event.
- stimthresh
float
The threshold level for accepting voltage changes in KIT trigger channels as a trigger event.
- preloadbool or
str
(defaultFalse
) Preload data into memory for data manipulation and faster indexing. If True, the data will be preloaded into memory (fast, requires large amount of memory). If preload is a string, preload is the file name of a memory-mapped file which is used to store the data on the hard drive (slower, requires less memory).
- stim_code‘binary’ | ‘channel’
How to decode trigger values from stim channels. ‘binary’ read stim channel events as binary code, ‘channel’ encodes channel number.
- allow_unknown_formatbool
Force reading old data that is not officially supported. Alternatively, read and re-save the data with the KIT MEG Laboratory application.
- standardize_namesbool
If True, standardize MEG and EEG channel names to be
"MEG ###"
and"EEG ###"
. If False (default), native channel names in the file will be used when possible.- verbosebool,
str
,int
, orNone
If not None, override default verbose level (see
mne.verbose()
and Logging documentation for more). If used, it should be passed as a keyword-argument only.
- input_fname
- Returns
- rawinstance of RawKIT
A Raw object containing KIT data.
See also
mne.io.Raw
Documentation of attribute and methods.
Notes
If mrk, hsp or elp are array_like inputs, then the numbers in xyz coordinates should be in units of meters.