mne.io.read_raw_snirf#
- mne.io.read_raw_snirf(fname, optode_frame='unknown', preload=False, verbose=None)[source]#
Reader for a continuous wave SNIRF data.
Note
This reader supports the .snirf file type only, not the .jnirs version. Files with either 3D or 2D locations can be read. However, we strongly recommend using 3D positions. If 2D positions are used the behaviour of MNE functions can not be guaranteed.
- Parameters:
- fnamepath-like
Path to the SNIRF data file.
- optode_frame
str
Coordinate frame used for the optode positions. The default is unknown, in which case the positions are not modified. If a known coordinate frame is provided (head, meg, mri), then the positions are transformed in to the Neuromag head coordinate frame (head).
- preload
bool
orstr
(defaultFalse
) Preload data into memory for data manipulation and faster indexing. If True, the data will be preloaded into memory (fast, requires large amount of memory). If preload is a string, preload is the file name of a memory-mapped file which is used to store the data on the hard drive (slower, requires less memory).
- verbose
bool
|str
|int
|None
Control verbosity of the logging output. If
None
, use the default verbosity level. See the logging documentation andmne.verbose()
for details. Should only be passed as a keyword argument.
- Returns:
- rawinstance of RawSNIRF
A Raw object containing fNIRS data. See
mne.io.Raw
for documentation of attributes and methods.
See also
mne.io.Raw
Documentation of attributes and methods of RawSNIRF.
Examples using mne.io.read_raw_snirf
#
Importing data from fNIRS devices