mne.io.read_raw_kit#
- mne.io.read_raw_kit(input_fname, mrk=None, elp=None, hsp=None, stim='>', slope='-', stimthresh=1, preload=False, stim_code='binary', allow_unknown_format=False, standardize_names=False, verbose=None)[source]#
- Reader function for Ricoh/KIT conversion to FIF. - Parameters
- input_fnamestr
- Path to the sqd file. 
- mrkNone|str| array_like, shape (5, 3) |listofstror array_like
- Marker points representing the location of the marker coils with respect to the MEG Sensors, or path to a marker file. If list, all of the markers will be averaged together. 
- elpNone|str| array_like, shape (8, 3)
- Digitizer points representing the location of the fiducials and the marker coils with respect to the digitized head shape, or path to a file containing these points. 
- hspNone|str|array, shape (n_points, 3)
- Digitizer head shape points, or path to head shape file. If more than 10,000 points are in the head shape, they are automatically decimated. 
- stimlistofint| ‘<’ | ‘>’
- Channel-value correspondence when converting KIT trigger channels to a Neuromag-style stim channel. For ‘<’, the largest values are assigned to the first channel (default). For ‘>’, the largest values are assigned to the last channel. Can also be specified as a list of trigger channel indexes. 
- slope‘+’ | ‘-’
- How to interpret values on KIT trigger channels when synthesizing a Neuromag-style stim channel. With ‘+’, a positive slope (low-to-high) is interpreted as an event. With ‘-’, a negative slope (high-to-low) is interpreted as an event. 
- stimthreshfloat
- The threshold level for accepting voltage changes in KIT trigger channels as a trigger event. 
- preloadbool or str(defaultFalse)
- Preload data into memory for data manipulation and faster indexing. If True, the data will be preloaded into memory (fast, requires large amount of memory). If preload is a string, preload is the file name of a memory-mapped file which is used to store the data on the hard drive (slower, requires less memory). 
- stim_code‘binary’ | ‘channel’
- How to decode trigger values from stim channels. ‘binary’ read stim channel events as binary code, ‘channel’ encodes channel number. 
- allow_unknown_formatbool
- Force reading old data that is not officially supported. Alternatively, read and re-save the data with the KIT MEG Laboratory application. 
- standardize_namesbool
- If True, standardize MEG and EEG channel names to be - "MEG ###"and- "EEG ###". If False (default), native channel names in the file will be used when possible.
- verbosebool | str|int|None
- Control verbosity of the logging output. If - None, use the default verbosity level. See the logging documentation and- mne.verbose()for details. Should only be passed as a keyword argument.
 
- input_fname
- Returns
- rawinstance of RawKIT
- A Raw object containing KIT data. 
 
 - See also - mne.io.Raw
- Documentation of attribute and methods. 
 - Notes - If mrk, hsp or elp are array_like inputs, then the numbers in xyz coordinates should be in units of meters. 
 
 